发布时间:2019-09-07 22:53 原文链接: 流式细胞仪技术专辑

 

最方便的实验干货查询工具

微信扫码进入「丁香实验」小程序

编辑: 呜咽

      

  • Flow Cytometry Analysis (Springer Lab, Harvard University)
    Flow cytometry employs instrumentation that scans single cells flowing past excitation sources in a liquid medium. The technology can provide rapid, quantitative, multiparameter analyses on single living (or dead) cells based on the measurement of visible and fluorescent light emission. Flow cytometry is a widely used method for characterizing and separating individual cells. This basic protocol focuses on: measure fluorescence intensity produced by fluorescent-labled antibodies and ligands that bind specific cell-associated molecules.
    Added: Wed Aug 14 2002 Reviews: 0   

     

  • Standard Flow Cytometry (FACS) Protocol (Jackson Lab)
    FACS Analysis Using Peripheral Blood Cells
    Added: Tue May 14 2002 Reviews: 0

     

  • Advanced Methodologies in Flow Cytometry (Cytomety Lab, Purdue Univ)
    A large collection of methodological paper on cytometry
    Added: Tue May 14 2002 Reviews: 0   

     

  • Annexin V Staining Protocol (BD PharMingen)
    A general protocol for staining cell for cytometry analysis.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Direct Immunofluorescence Staining (U of Florida Flow Cytometry Core Laboratory)
    This is the method for direct immunofluorescence labeling; that is, the antibodies have the fluorescent dye attached. Direct labeling is simpler and quicker than indirect labeling.
    Added: Tue May 14 2002 Reviews: 0   

     

  • FCM of leukocytes in whole blood (David Chambers)
    Added: Tue May 14 2002 Reviews: 0   

     

  • Fixation and DNA Staining for Cell Cycle Analysis (U of Florida Flow Cytometry Core Laboratory)
    This method of DNA staining utilizes ethanol to fix the cells and permeabilize the membrane, which allows the dye (Propidium Iodide) to enter the cells.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Fixation of Immunofluorescence-Labeled Samples (U of Florida Flow Cytometry Core Laboratory)
    This fixation method is good for cells labelled by fluorochrome-conjugated antibodies to membrane antigens.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Flow Cytometric Analysis of Cell Cycle (Hannun/Obeid Lab)
    Protocol for fixing and staining
    Added: Tue May 14 2002 Reviews: 0

     

  • Flow Cytometry Assay to measure Internalization of GPCR's (Von Zastrow lab)
    Internalization of receptor is measured as the reduction of receptors on the plasma membrane surface. Surface receptors are labeled with fluoresent antibodies which is in turn measured using a flow cytometer. The antibodies recognize an epitope engineered onto the N-terminus of the GPCR.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Flow Cytometry: Indirect Immunofluorescence Staining of Human Platelets (BD Pharmingen)
    Protocol for general use.
    Added: Sat Jul 27 2002 Reviews: 0   

     

  • Fluorescein Labeling (David Chambers)
    Added: Tue May 14 2002 Reviews: 0   

     

  • Immunodetection of cyclin D1 and D2/D3 using 488/630 nm ( )
    dual laser flow cytometry(Cytomety Lab, Purdue Univ)
    This protocol is for use with the D cyclins and employs 488 nm argon laser excitation of propidium iodide and 630 nm NeNe or diode laser excitation of the fluorochrome Cy5 to detect cell cycle-specific cyclin D expression
    Added: Tue May 14 2002 Reviews: 0   

     

  • Immunofluorescence Staining and Flow Cytometry of Intracellular Cytokines (eBioscience)
    A modification of the basic immunofluorescence staining and flow cytometric analysis protocol can be used for the simultaneous analysis of surface molecules and intracellular cytokines at single-cell level. In this protocol, cells are first activated in vitro, stained for surface antigens, as in the regular staining protocol, then fixed and permeabilized to allow for anti-cytokine antibodies to stain intracellularly.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Immunofluorescence Staining of Human Cells by Lysed Whole Blood Method (BD PharMingen)
    Standard protocol
    Added: Wed Aug 28 2002 Reviews: 0

     

  • Immunofluorescent Staining of Mouse and Rat Leukocytes (BD PharMingen)
    Standard protocol including detailed procedures and tips
    Added: Wed Aug 28 2002 Reviews: 0   

     

  • Indirect Immunofluorescence Staining (U of Florida Flow Cytometry Core Laboratory)
    This is the method for indirect immunofluorescence labeling; that is, the antibodies do not have the fluorescent dye attached.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Paraformaldehyde preparation ( )
    Added: Tue May 14 2002 Reviews:

     

  • Phenotype-specific immunodetection of cyclins using 488/630 nm dual laser flow cytometry (Cytomety Lab, Purdue Univ)
    This protocol is for use with the D and E cyclins and employs 488 nm argon laser excitation of propidium iodide and a FITC-conjugated phenotypic label, and 630 nm NeNe or diode laser excitation of the fluorochrome Cy5 to detect cell cycle-specific cyclin D expression.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Phycoerythrin Labeling (David Chambers)
    Added: Tue May 14 2002 Reviews: 0  Write review

     

  • Protein (Antibody) Fluorescent Labeling (Mario Roederer)
    Gives detailed protocol for conjugation of proteins (principally monoclonal antibodies) to fluorescent dyes. The conjugations fall into four basic protocols: Type 1 (used for FITC, Cy5, and the initial preparation of the Cy5 and Cy7 tandem dyes); Type 2 (used for Biotin and Cascade Blue); Type 3 (used for conjugation of PE, APC, TR-BSA, and their derivatives); and Type 4 (used for the initial preparation of non-immunoglobulin proteins like Annexin V).
    Added: Tue May 14 2002 Reviews: 0   

     

  • Simultaneous analysis of DNA content and surface immunophenotype using gentle ethanol fixation (Cytomety Lab, Purdue Univ)
    This procedure utilizes gentle ethanol treatment techniques, which permeablize cells with minimal loss of surface antigen expression and antibody-antigen association.
    Added: Tue May 14 2002 Reviews: 0   

     

  • Staining Procedure for Flow Cytometric Detection of Human Cyclins (BD PharMingen)
    This is a standard protocol used at Pharmingen for Quality Control testing of the anti-cyclin antibodies by flow cytometry. It is a good starting point. However, investigators may need to optimize protocols for their own experimental system. It is particularly useful to refer to the published literature regarding protocols typically used for a given type of protein.
    Added: Wed Aug 28 2002 Reviews: 0   

     

  • Yeast Cell Cycle Analysis by Flow Cytometry (Susan Forsburg)


相关文章

985.1万,首都医科大学一流医学教育与高精尖创新科研设备提升更新项目之一中标公告

一、项目编号:11000025210200147094-XM001二、项目名称:首都医科大学一流医学教育与高精尖创新科研设备提升更新项目之一三、中标(成交)信息总中标成交金额:985.1万元(人民币)......

857万,吉安中心人民医院采购液质等6套仪器设备

2025年9月20日,江西省公共资源交易平台就吉安市中心人民医院就“临床研究中心实验室及传染病医院设备项目”发布招标公告。公告显示,本次招标预算总金额为857万元,采购设备共计6套,包括全自动分歧杆菌......

碧迪医疗首台本土化生产流式细胞仪BDFACSLyricz正式投入生产

美通社消息,2025年8月8日,碧迪医疗首台本土化生产的流式细胞仪BDFACSLyric正式投入批量生产。来自政府、临床客户、合作用户及碧迪医疗管理层的各高层领导及嘉宾代表出席了在碧迪快速诊断产品(苏......

1795万元西安交大一附院计划采购流式细胞仪等一批仪器设备

西安交通大学第一附属医院近日公布一批政府采购意向,其中部分涉及分析仪器,包括流式细胞仪、高分辨激光共聚焦显微镜等,这些设备的预算金额为1795万元。为便于供应商及时了解采购信息,现将采购意向整理如下:......

首款!碧迪医疗宣布高端高端流式细胞仪实现中国本土化生产

近日,随着在华获得医疗器械注册证,碧迪医疗旗下的流式细胞仪BDFACSLyric的本土化生产项目进入全面冲刺阶段,并将于今夏面世。这将是碧迪医疗首次把高端流式细胞仪的生产引入中国,不仅标志着公司在华本......

新疆疾控54台大手笔采购该品牌流式细胞仪助力公卫新高度

近日,新疆维吾尔自治区疾病预防控制中心(以下简称“新疆疾控”)公布了流式细胞仪采购项目的结果公告,此次共采购54台流式细胞仪,安捷伦的NovoCyte流式细胞仪中标了此项目。新疆疾控作为地区公共卫生体......

碧迪发布致客户的公开信——关于美国高维流式禁令的应对方案

今日,碧迪医疗(BD)发布有关2025年1月16日美国前政府发布的近期临时最终规则(IFR)的最新进展,称其一直在积极与美国政府沟通,力求对该规则进行修订。“目前,该规则正在接受审查,在此期间,碧迪医......

索尼、赛默飞等中标这一重点实验室重大设备更新进口科研设备项目

近日,云南大学省部共建云南生物资源保护与利用国家重点实验室教育领域重大设备更新进口科研设备项目采购结果公布,Sony、ThermoFisher、Berthold三品牌分别中标此次招标项目中的光谱成像流......

索尼宣布在华启动流式细胞仪本土化生产

2025年2月26日,北京——为积极响应中国政府关于推动生命科学仪器国产化的政策号召,索尼集团今日正式宣布,自2025年4月1日起,旗下部分流式细胞仪型号将在中国实现本土化生产。此举标志着索尼在深化本......

贝克曼库尔特与RarityBioscience达成合作拓展临床研究分子流式细胞技术新可能

印第安纳波利斯—(2025年3月5日)—全球实验室自动化与创新领域的领导者贝克曼库尔特生命科学公司,携手RarityBioscienceAB,通过将流式细胞术的应用拓展至临床分子研究,为肿瘤学研究带来......