发布时间:2019-04-26 20:44 原文链接: CombinedFlowCytometricMeasurementofTwoCellSurfaceAntigens2

DNA and RNA Staining


  • 6. Stain cells with 7-AAD: 

    • i. Resuspend the cells from Step 5 in 0.5 mL of NASS containing 10 µg/mL of 7-AAD. Incubatefor 20 min at 20°C-25°C, protected from light. 

    • ii. Prepare a cell sample that is stained only with 7-AAD (without any cell surface staining). 
      This sample is necessary to determine the amount of fluorescence overlap of 7-AAD into other detectors on the flow cytometer and to set the appropriate fluorescence compensation. 

  • 7. Add 1 mL of 1X PBS to each sample. Collect the cells by centrifugation at 250g for 5 min. Discard the PBS. 

  • 8. Stain cells with PY: 

    • i. Resuspend each cell pellet in 0.5 mL of NASS containing 10 µg/mL of AD. Place the mixtureon ice for 5 min, protected from light. 

    • ii. Add 5 µL of a 1:10 dilution of the PY stock solution (made with H2O), and vortex immediately. Keep the cells on ice, protected from light, for at least 10 min before sample acquisition on the flow cytometer. 
      It is possible to keep cells in the staining solution protected from light at 4°C for a maximum of 3 d before sample acquisition on the flow cytometer, without adverse effects. 

    • iii. Prepare a sample of cells stained only with PY (without any cell-surface or 7-AAD staining). 
      This sample is necessary to determine the amount of fluorescence overlap of PY into other detectors on the flow cytometer and to set the appropriate fluorescence compensation. 

  • 9. Run samples on the flow cytometer using a low sample differential. Collect the fluorescence signals for cell-surface immunofluorescence with log amplification. Collect the DNA and RNA signals with linear amplification (Fig. 1 ). 

    Figure 1
    View larger version (24K):
    [in this window]
    [in a new window]

     
    Figure 1. Application of the method for concurrent flow cytometric measurement of two cell-surface antigens and DNA-RNA content. Human peripheral blood mononuclear cells were cultured for 72 h, either in medium alone (A-D) or in medium containing 100 ng/mL of soluble CD28.2 (Biodesign) in the presence of 100 ng/mL of surface-bound OKT3 (Ortho Diagnostics) (E-H). (C and G) Analysis of CD5+CD8+ T cells; RNA/DNA dot-plots were gated on scatter as shown in row 1 (in A and E) and R1 (in B) or R2 (in F), respectively. (D and H) Analysis of CD5-CD8+ cells; RNA/DNA dot-plots were gated on scatter as shown in row 1 (in A and E) and on R3 (in B) or R4 (in F), respectively. After 3 d in culture without stimulation, CD8+ cells, irrespective of CD5 expression, did not leave G0. As expected, with CD3/CD28 activation, CD8+ cells that coexpressed CD5 (a human T lymphocyte antigen) proliferated, while CD5-CD8+ (NK cells) remained in G0. After 72 h of costimulation, only 9% of CD5+CD8+ T cells remained in G0; ~15% were in G1a, 21% were in G1b, and the rest were represented in the S + G2+M phases of the cell cycle.

    Running samples at a low sample pressure lowers the coefficient of variation (CV) of the DNA measurement. Low CVs improve the accuracy of data analysis by facilitating deconvolution of DNA histograms by flow cytometry DNA analysis software programs. See Troubleshooting. 
    A standard practice employed for reliable DNA analysis is doublet discrimination. This can be achieved by acquiring area and width signals in the channel used for measuring DNA fluorescence. If this is not possible due to instrument limitations, displaying area versus height signals or gating on light scatter signals (Fig. 1) can also be used to exclude cell aggregates during data analysis. 


TROUBLESHOOTING

Problem: The DNA profiles have a high CV.

[Step 9]

Solution: The low pH of the NASS improves access of 7-AAD to the DNA, resulting in DNA staining with low CV. Despite this, samples that are run through the flow cytometer at high sample pressure will be measured with decreased precision and higher CVs. In addition, there is fluorescence overlap between 7-AAD and PY. If the overlap is not compensated correctly, the 7-AAD peaks will widen. Also, if substantial numbers of cells are dying, their degrading DNA will lead to broad DNA distributions. Solutions involve removing dead cells by Ficoll gradient orchoosing an earlier time point for analysis (before the cells start to die).

Problem: The detection of cellular subpopulations needs improvement.

Solution: This protocol was optimized for detection of surface antigens by using low nucleic acid dye concentrations and exchanging 7-AAD with nonfluorescent AD. This serves to reduce background fluorescence caused by the dyes in solution and to minimize fluorochrome interactions. Data obtained with these low concentrations matched the results obtained for DNA-RNA staining with standard concentrations of 7-AAD and PY. Therefore, because nucleic aciddye concentrations must be maintained at the levels described in the Method section, strategies to improve the brightness of signal detection should focus on the mAb staining step (Step 2). These strategies involve selecting the brighter fluorochrome for the cell-surface antigen with low abundance, titrating the mAb to achieve the best separation between background and positivecells, using indirect staining to amplify the fluorescent signal, and selecting different mAb clones that may provide better staining.


DISCUSSION

In mixed-cell preparations, analysis of surface antigen expression in combination with cell-cycle events is essential for the determination of the growth status of cellular subpopulations. Measurement of DNA content by flow cytometry using different fluorescent dyes for staining DNA is compatible with simultaneous detection of cell surface antigens, but only identifies the three basic phases of the cell cycle: G0/1, S, and G2+M. Cells that are actively progressing through the S phase can be identified in flow cytometry by combining measurement of DNA content with bromo-deoxyuridine (BrdU) incorporation, an assay comparable to the assessment of thymidine incorporation using a radioactive label. However, the DNA denaturation step required in many BrdU staining protocols to make incorporated BrdU accessible to anti-BrdUantibodies can affect simultaneous detection of other immunochemical parameters. Bivariate analysis of DNA content and cyclin expression, which varies during cell-cycle progression, provides a framework for the subdivision of the cell cycle into distinct subcompartments. The success of this technique relies on suitable cell-fixation, cell-permeabilization, and dependable antibodies specific for the various types of cyclin proteins that have been proven to work in flow cytometry.

In addition to DNA content, the determination of RNA content is another approach for assigning cells to various cell-cycle compartments and for discriminating G0 from different stages within G1. Several techniques have been developed for DNA-RNA content measurement by flow cytometry. One method involves differential staining of DNA-RNA with acridine orange (AO) (Darzynkiewicz et al. 1980). Accurate measurement of DNA-RNA content using AO is rather complex and depends on stringent staining conditions. In addition, AO, due to its broad emission spectrum, cannot be combined with other common fluorochromes used for antibody labeling. Another method is the simultaneous analysis of DNA and RNA content using Hoechst 33342 and PY (Shapiro 1981). This assay requires ultraviolet excitation, which is not available on most benchtop flow cytometers. Alternatively, Toba et al. (1995) described a 7-AAD/PY DNA-RNA staining method that is compatible with cell-surface antigen staining with fluorescein-isothiocyanate (FITC)-labeled antibodies.

This protocol describes a method optimized for the concurrent measurement of two cell-surface antigens using a standard dual-laser flow cytometer. Cell-surface staining is presented using oneantibody that is directly labeled with APC, and a second, biotinylated antibody that is detected with Alexa Fluor 488-labeled streptavidin (Fig. 1). If a given cell-surface antigen is expressed at high levels, mAbs that are directly conjugated to Alexa Fluor 488 can be used, shortening the time required for staining. Conversely, it is possible to use one unlabeled mAb that is then detected with a fluorochrome-labeled species-specific antiserum. This strategy can be used to amplify the signal obtained with low-abundance cell-surface antigens. Note, however, that for dual cell-surface labeling, the first and second staining steps for the unlabeled mAb need to be completed before staining with the other, directly labeled mAb. Otherwise, the antiserum will bind to both mAbs (unless each was made in a different species).

New fluorochromes have recently become available for flow cytometry that may be compatible with this protocol. The selection of fluorochrome labels for cell-surface staining with emissionsthat can be separated from the emissions of 7-AAD (peak emission at 650 nm) and PY (peak emission at 580 nm) is necessary. The fluorochromes must also be compatible with the acidic NASS solution (pH 4.8). For instance, fluorescein isothiocyanate (FITC) cannot be used, because FITC fluorescence is lost in acidic solutions. Before new labels are incorporated into this staining protocol, it is necessary to determine whether they retain sufficient brightness for detection of a given cell-surface antigen.


相关文章

科学家将人工智能技术成功用于蛋白质复合物结构预测

蛋白质作为构成人体组织器官的支架和主要物质,在人体生命活动中起着重要作用。蛋白质的相互作用能产生许多效应,如形成特异底物作用通道、生成新的结合位点、失活、作用底物专一性和动力学变化等,细胞的代谢、信号......

发力癌症分子病理诊断,无锡臻和全资收购TissueofOrigin®

2021年9月9日,无锡臻和生物科技有限公司(以下简称“臻和科技”)与美国VyantBio公司签署TissueofOrigin®(以下简称“TOO®”)全球权益和ZL转让协议,全资收购这款唯一获FDA......

这3个杂志撤回中国学者249篇文章,包含上交、中山等名校

2021年7月20日,JournalofCellularPhysiology及JournalofCellularBiochemistry同时撤回了中国学者49篇文章。从2019年开始,Journalo......

肿瘤治疗的强心剂,中国学者开发肿瘤治疗新策略

磷酸甘油酸突变酶1(PGAM1)通过其代谢活性以及与其他蛋白质(例如α平滑肌肌动蛋白(ACTA2))的相互作用,在癌症代谢和肿瘤进展中起关键作用。变构调节被认为是发现针对PGAM1的高选择性和有效抑制......

硬核原创FlowLab:化工制药业绿色安全生产的法宝

分析测试百科网讯,今年来化工厂的频繁爆炸事件造成极大社会反响,化工生产中的安全问题再次触动了所有国人的神经。安全排查、人员责任等手段固然能起到一定的效果,但还不能从根本上解决问题;分析诸多事件,我们发......

llumina宣布推出新型基因分型芯片|支持AllofUs研究计划

2018年12月6日,来自圣迭戈的消息——Illumina公司(纳斯达克股票代码:ILMN)今天宣布推出新型高密度基因分型芯片Infinium™GlobalDiversityArray。这款芯片设计源......

珀金埃尔默推出FTNIR新品SpectrumTwoN

分析测试百科网讯近日,珀金埃尔默推出近红外新品SpectrumTwoNFT-NIR。该仪器专为实验室技术人员和工作人员进行广泛的制药,食品和工业样品的分子光谱分析。SpectrumTwoNSpectr......

采用USEPA方法OIA1677和FlowSolution®IV测量有效的氰化物

这里描述了按照USEPA方法OIA-16771-4,通过价位交换、流动注射分析(FIA)和安培计检测有效氰化物的方法。这个方法用于USEPA关于清洁水法案,资源保护与回收法案,全面环境响应,补偿与责任......

SDSPAGE异常电泳现象及分析SDSPAGEHallofShame

SDS-PAGE异常电泳现象及分析SDS-PAGEHallofShame.pdf  很不错的东东~~推荐下~......

精品:GeneFlowfromGMPlants+好书一本

今天在网上淘到的一本书GeneFlowfromGMPlants,05年,还算比较新。望大家多多支持。GeneFlowfromGMPlantsEditedbyGUYM.POPPYSchoolofBiol......