Although most people use the PhosphorImager for western blots, kinase assays and methionine-labeled samples, X-ray film remains the best way to expose peptide maps and prep gels. 




Terminology


Autoradiography is the direct exposure of film by beta particles or gamma rays. 

Fluorography is the exposure of film by secondary light that was generated by the excitation of a fluor or a screen by a beta particle or a gamma ray.




Fluorography works best with flashed film and exposure of the film at - 70°C. The flashing particularly helps the detection of weak bands or spots. In some circumstances there is a threshold below which nothing can be detected. Flashing reduces this threshold. 



Detection of 3H.

3H cannot be detected by autoradiography unless you have 1 mCi of it in your band. Because this is almost unheard of, it is essential to impregnate a gel containing 3H with PPO or Enlightening or to spray a 3H-containing TLC plate with spray Enhance or some such product in order to detect tritium. 

In both cases exposure should be with flashed film at - 70°C.





Detection of 35S and 14C.

35S and 14C can be detected by autoradiography. Simply expose your sample with unflashed film at room temperature or use the PhosphorImager. 




Detection of 32P and 125I.


32P and 125I can also be detected by autoradiography. Just expose your sample with unflashed film at room temperature.

Note that the image provided by direct autoradiography is always sharper than is the image resulting from fluorography.

Exposure with both isotopes can be accelerated greatly through the use of a screen.

When using a screen put flashed film between the screen and the gel or TLC plate and expose at -70°C.

Note that the film is exposed in two ways this way: directly by beta particles from the gel and secondarily by light from the screen. The majority of the exposure is from the screen. It is this side of the film that should be the so-called flashed side--see below.

Alternatively, use the PhosphorImager.




Screens do not enhance 3H, 14C or 35S. 

PPO and Spray enhance do not enhance the detection of 32P or 125I.


Exposure at -70°C does not enhance autoradiography. It does not hurt it however




Note: X-ray film has emulsion on both sides. It is useful therefore to keep track of which side of the film was up when the film was flashed. The film is quite opaque and the emulsion on the side facing the PPO'ed gel or the screen is exposed much more efficiently by the emitted light than is the other emulsion.


It seems likely in addition that flashing fogs the top emulsion more than the bottom emulsion. It is this side of the film that is referred to colloquially as the flashed side of the film. Therefore, to get the most out of flashing, the flashed side of the film should be put facing the PPO'ed gel or facing the screen, depending on which isotope is being detected.


相关文章

美国TO设备助阵,第六届上海市力学竞赛团体赛圆满成功

2024年11月9日,由上海市力学学会主办、同济大学承办的第六届上海市大学生力学竞赛团体赛在同济大学举行。来自同济大学、上海交通大学、复旦大学、华东师范大学、上海大学、上海工程技术大学、上海师范大学、......

苏州学者研究出新型X射线响应纳米载药系统

化疗是临床上常用的肿瘤治疗方式,但是单分子化疗药物生物利用度低、治疗副作用大,给患者身心及其家庭带来负担。利用纳米技术将单分子化疗药物制备成纳米药物,可实现化疗药物肿瘤靶向和可控释放,从而改善治疗效果......

肿瘤治疗的强心剂,中国学者开发肿瘤治疗新策略

磷酸甘油酸突变酶1(PGAM1)通过其代谢活性以及与其他蛋白质(例如α平滑肌肌动蛋白(ACTA2))的相互作用,在癌症代谢和肿瘤进展中起关键作用。变构调节被认为是发现针对PGAM1的高选择性和有效抑制......

冷冻电镜&Xray

X-ray的技术问题十年前就已经基本解决了,剩下的就是生物狗们怎么长晶体。而现在的冷冻电镜就如十五年前的X-ray,搞技术的人都涌进了这个领域,冷冻电镜的潜力还没有被彻底挖掘,个人感觉还会再火一阵。冷......

SerialFemtosecondCrystallography的基本原理是什么?

X-rayDiffraction。区别于同步辐射X-rayCrystallography的最大之处在于光源特点的不同。......

布鲁克公司完成对JordanValley半导体有限公司的收购

分析测试百科网讯布鲁克公司在2015年11月2日宣布完成对JordanValley半导体有限公司的收购,JordanValley半导体有限公司是一家提供X射线测量和半导体过程控制缺陷检测的公司。有了J......

新仪器有助加快机场安检

   自去年实施机场反恐安检新举措以来,英国各大机场登机乘客只能携带一件手提行李,给乘客带来不便,但是这种局面现在有望得到改变。   一种可......