发布时间:2019-07-07 13:05 原文链接: COMPETITIONELISA

The ELISA protocols for detection of the antibody binding to an antigen-coated microtitre plate are standard laboratory techniques and will not be described here. We will just mention that most recombinant antibody fragments are typically detected using monoclonal antibodies directed against a peptidic tag engineered at the C-terminal extremity of the recombinant antibody. In certain experimental conditions, such peptidic tags may undergo proteolytic cleavage, thereby lowering the sensitivity of antibody detection. Reagents that bind to the antibody molecule without impairing antigen binding (e.g., protein A or protein L) may therefore be preferable. Alternatively, the experimental scheme described below can be performed in a similar fashion, using radiolabeled antibodies and radioacitve detection of antibody-mediated antigen binding. The concentration of purified antibody preparations is typically determined spectrophotometrically (1 mg/ml antibody solution absorbs 1.4 absorption units at 280 nm). If necessary (for example when using supernatants), the concentration of active antibody can be detected with a straightforward ELISA adaptation of the protocol mentioned above for the determination of antibody concentration by band-shift assay.

  1. Coat with antigen (in identical fashion) an appropriate number of wells of two microtitre plates. Preblock the wells with 3% MPBS for 2 hours at room temperature, then wash with PBS.

  2. In parallel tubes, incubate an antibody solution (at concentrations below Kd, e.g. 0.5 nM) with increasing concentrations of antigen (e.g., ranging between 0.1 nM and 1 µM) in PBS [total volume of each reaction: 100 µl].

  3. After 30 minutes incubation at room temperature, apply 90 µl of the reaction mixtures to the wells of the first antigen-coated microtitre plate (perform the experiment in duplicate or triplicate), containing 30 µl 10% MPBS.

  4. Incubate the reaction mixture on the antigen-coated plate for a suitably short time (e.g., 10 min.).

  5. After incubation, transfer the reaction mixtures to the second antigen-coated microtitre plate. The ELISA assay using this second plate will now be performed exactly as for the first microtitre plate. The purpose of the second ELISA assay is to check that only a small fraction of the free antibody is captured on the first microtitre plate and, therefore, no readjustment of the equilibrium occurred during the first capture step.

  6. Wash extensively the first ELISA plate and perform the remaining steps of an ELISA procedure, aimed at the determination of the antibody binding to the coated antigen.

  7. Develop the ELISA with a suitable chromogenic, fluorogenic or chemiluminescent substrate, and measure the individual wells with an appropriate ELISA plate reader. The highest ELISA signal should be observed at low concentrations of antigen. No ELISA signal should be observed at high concentrations of antigen. The concentration of antigen at which the half-maximal ELISA signal is detected corresponds to the dissociation constant Kd. Alternatively, the Kd value can be obtained by fitting the ELISA signal of the individual wells to the equation: Kd = [A][B]/[AB] .



相关文章

大观霉素间接竞争性ELISA的建立及应用

大观霉素(spectinomycin,SPE)是一种氨基糖苷类广谱抗生素,是Mason于1961年首次从链霉菌中分离得到[1]。从结构上讲,氨基糖苷类抗生素分子中均含有氨基糖苷结构。而SPE(图1)是......

ELISA分析缺点

ELISA实验所有方法的缺点很明显:1、重复性不好;2、收自身抗体、嗜异性抗体等干扰,易出现假阳性;3、不论仪器和手工操作,干扰因素较多。影响最大的是温度和时间。1、直接法(directELISA)将......

酒中的草甘膦对人体健康的影响

最近,科学家们在啤酒和葡萄酒中发现了一种常见的杂草杀手—草甘膦。此前,它曾因其可能与癌症有关而引起争议。美国的研究人员测试了15种不同类型的啤酒和5种不同类型的葡萄酒,在20种饮料中的19种中发现了农......

ELISA的原理

ELISA的原理:(1)抗原或抗体能以物理性吸附于固相载体表面,可能是蛋白和聚苯乙烯表面间的疏水性部分相互吸附,并保持其免疫学活性;(2)抗原或抗体可通过共价键与酶连接形成酶结合物,而此种酶结合物仍能......

农业部公告第2593号牛支原体ELISA试剂盒等2种新兽药

根据《兽药管理条例》和《兽药注册办法》规定,经审查,批准中国农业科学院哈尔滨兽医研究所等6家单位申报的牛支原体ELISA抗体检测试剂盒等2种兽药产品为新兽药,核发《新兽药注册证书》,并发布产品试行规程......

ELISA实验中常见问题和注意事项

1临床标本的收集和保存用于ELISA测定的临床标本最为常用的是血清(浆)。本实验室用ELISA测定乙肝两对半,甲肝,戊肝,抗HIV的标本时,在处理和保存方面要考虑以下几个方面:1)要注意避免出现严重溶......

消除ELISA假阳性的改进措施

当你拿着化验单询问医生,他/她却告诉你需要做更多检查,你的心情想必更加焦虑。例行公事的医学检查好比针对潜在疾病的一场排雷竞赛。医生和患者们都如履薄冰,尽管执行了正确的检验,但其结果却错误地把不具备阳性......

ELISA实验的18条军规,你知道吗?

ELISA实验通用规则1、要保证移液枪的准确性,误差不能超过2%。可用水和电子天平进行确定。但最好有专业人员进行矫正。2、要配备20ul、50ul、100ul、1000ul和排枪各一支。吸取不同的液体......

复旦研发激光ELISA助力重大疾病早期检测

4月30日,国际著名科学期刊《自然-通讯》(NatureCommunications)发布了一种新型的光微流激光酶联免疫吸附剂测定(Enzyme-linkedimmunosorbentassay,简称......

自动化ELISA技术

在一般的概念里,ELISA技术的可操作性强,不需复杂设备,甚至完全手工加样、洗板和肉眼判读结果,便可完成该技术的操作。随着人们对质量控制意识的加强,尽可能做到最低限度的减少系统误差,以及减少劳动强度等......