Equipment: Syringe and 23 to 27 g, 1/2 to 1-inch needle, preferably with a short bevel.
Volume: The volume injected IP into an adult mouse should not exceed 2 ml.
The mouse is grasped as previously described, and held in dorsal recumbency in a head-down position. The injection is made in the lateral aspect of the lower left quadrant (picture). The use of a short bevel needle inserted through the skin and musculature and immediately lifted against the abdominal wall, aids in avoiding puncture of the abdominal viscera. Immobilizing the left leg is also essential in reducing this risk. Rapid injection, especially with a large syringe, may cause discomfort and tissue damage and should be avoided.
Equipment: Syringe and 25 to 27 g, 1/2 to 3/4-inch needle.
Volume: The volume injected SQ into an adult mouse should not exceed 2-3 ml.
This route is frequently used as an alternative to intramuscular injections in the mouse. The site usually chosen is the loose skin between the shoulder blades. Alternatively, the ventral abdomen is commonly used, employing one handed restraint (picture). The needle is inserted through the skin and advanced 5 to 10 mm through the subcutaneous tissue to prevent leakage from the site.
Equipment: Syringe and 26 to 30 g, 1/2-inch needle.
Volume: The volume injected intramuscular in the adult mouse should not exceed 0.05 ml.
This route is usually not used and is not recommended because of the small muscle mass available and the danger of damaging vital structures. However, when it is used, the back and hind leg muscles are the usual sites selected.
The amount of blood needed and other factors will govern the method and sites of collection. Table I (future table) lists common blood withdrawal sites in laboratory animals and precautions and requirements for these procedures. Descriptions of the various techniques for venipuncture in different species is available in the Animal Care Unit (400 ML; 335-7985) in text and videotape format. Proper insertion of the needle into a vein or other part of the vascular system is normally the most difficult part of the procedure. Certain guidelines can be given, but only practice provides proficiency. Veins may be expected to roll, collapse, or shift, making entrance difficult. A precise, careful introduction of the needle is best and several attempts may be required. Starting at distal sites will allow repeat attempts more proximally. The needle is inserted parallel to the vein and the tip directed into the lumen along the longitudinal axis. When withdrawing blood from a vein, aspiration should be slow so the vessel does not collapse.
The area of injection or incision should be cleaned with alcohol. Some procedures will require sedation or anesthesia; others may be carried out without anesthesia provided suitable restraint is used. In order to better visualize veins dilation can be accomplished by immersing the tail in warm water for 5 to 10 seconds or by warming the animal with a low-wattage light bulb for 5 to 15 minutes prior to venipuncture. This also aids by providing additional light.
Equipment: scalpel blade, 25 to 30 gauge needle
The mouse is restrained (picture1; picture2) using a mechanical device. The veins may be seen laterally near the base of the tail but good illumination and dilation will normally be required. A small blood sample may be collected by capillary action using a microhematocrit tube inserted into the hub of a small needle previously placed into the tail vein (future picture). This technique normally recovers a few drops of blood, adequate for hemoglobin, microhematocrit and cell counts.
Larger blood samples can be obtained by making a small incision over the vessels 0.5 to 2 cm from the tail base using a scalpel blade. One half to one milliliter of blood can be withdrawn using this method. Anesthesia or sedation should be used.
Toe clipping or tail clipping to obtain blood samples: Clipping toes is an unacceptable method of blood collection. Tail clipping is not a preferable method for blood collection.
Equipment: 0.90 to 0.50 mm needle
Cardiac puncture represents an accepted method of blood collection from mice when more than a few drops are required. However, this method also carries considerable risk to the animal and occasionally deaths occur. It is not recommended as a repetitive blood sampling procedure. Animals must be anesthetized and restrained in dorsal recumbency. The needle is inserted under the xyphoid cartilage slightly to the left of midline (picture). The needle is advanced at a 20 to 30 degree angel from the horizontal axis to the sternum to enter the heart. Aspirate lightly while advancing. Blood should be withdrawn slowly, and the amount must be limited (up to 1 ml) unless euthanasia is planned.
Equipment: Capillary tubes
Blood collection from the orbital sinus of mice is frequently used. One quarter ml can be repeatedly collected from mice at weekly intervals from alternate sides. Bleeding requires that the tube be directed into the orbital sinus (picture, picture) which surrounds the globe. In the mouse, the tube is inserted into the medial canthus of the eye and directed caudally and slightly dorsally. Knowledge of the location of the venous structures of the orbit of the mouse aids in establishing a successful peri-orbital bleeding technique. Pressure should be applied after blood collection to prevent hematomas. Anesthesia is required for all peri-orbital bleeding procedures.
Equipment: scalpel blade 3 to 5 cc syringe
Blood can be collected from the axillary region in a terminal exsanguination. Exsanguination of the mouse can be achieved by incising the right or left axillary region of an anesthetized mouse in dorsal recumbency. One to two ml of blood can be harvested in this manner.
蛋白质作为构成人体组织器官的支架和主要物质,在人体生命活动中起着重要作用。蛋白质的相互作用能产生许多效应,如形成特异底物作用通道、生成新的结合位点、失活、作用底物专一性和动力学变化等,细胞的代谢、信号......
2021年9月9日,无锡臻和生物科技有限公司(以下简称“臻和科技”)与美国VyantBio公司签署TissueofOrigin®(以下简称“TOO®”)全球权益和ZL转让协议,全资收购这款唯一获FDA......
2021年7月20日,JournalofCellularPhysiology及JournalofCellularBiochemistry同时撤回了中国学者49篇文章。从2019年开始,Journalo......
研究阐明了SETD2在调控骨髓增生异常综合征(MDS)向急性髓系白血病(AML)转化过程中的作用机制,为MDS临床治疗提供了理论基础和潜在靶标。MDS是最常见的髓系恶性肿瘤之一,是起源于造血干细胞的一......
为什么有些癌症治疗之后仍会复发?有时候,癌症的相关治疗可以有效地将癌细胞消除到无法检测的水平,但是,如果停止治疗,癌症可能会复发。例如,在用酪氨酸激酶抑制剂药物治疗慢性粒细胞白血病患者是就会出现停药后......
化疗已使最常见的儿童期癌症---急性淋巴细胞白血病(ALL)---成为最可治愈的癌症之一,但是科学家们有证据表明这种治疗也可能使某些患者复发。在一项新的研究中,来自中国和美国的研究人员报道由治疗引起的......
磷酸甘油酸突变酶1(PGAM1)通过其代谢活性以及与其他蛋白质(例如α平滑肌肌动蛋白(ACTA2))的相互作用,在癌症代谢和肿瘤进展中起关键作用。变构调节被认为是发现针对PGAM1的高选择性和有效抑制......
磷酸甘油酸突变酶1(PGAM1)通过其代谢活性以及与其他蛋白质(例如α平滑肌肌动蛋白(ACTA2))的相互作用,在癌症代谢和肿瘤进展中起关键作用。变构调节被认为是发现针对PGAM1的高选择性和有效抑制......
2018年12月6日,来自圣迭戈的消息——Illumina公司(纳斯达克股票代码:ILMN)今天宣布推出新型高密度基因分型芯片Infinium™GlobalDiversityArray。这款芯片设计源......
在一项新的研究中,来自美国俄亥俄州大学的DaniloPerrotti和同事证实一种叫做FTY720的药物能够抑制由癌症蛋白BCR-ABL导致的白血病小鼠模型的病情。由于这种药物还能够诱导从白血病患者获......