实验概要
The E.Z.N.A.™ family of products is an innovative system that radically simplifies extraction and purification of nucleic acids from a variety of sources. Key to the system is the Omega Bio-tek’s proprietary HiBind® matrix that avidly, but reversibly, binds DNA or RNA under certain optimal conditions allowing proteins and other contaminants to be removed. Nucleic acids are easily eluted with deionized water or low salt buffer.
The E.Z.N.A.™ Fastfilter Plasmid Mega Kit combines time-tested consistency of alkaline-SDS lysis of bacterial cells with Omega Bio-tek’s innovative high efficiency DNA binding technology to recovery large scale high quality plasmid DNA. This new methods facilitate the binding, washing, and elution steps thus enabling multiple samples to be simultaneously processed. This kit uses a Syringe-Format System is designed to replace the centrifugation step following alkaline lysis of bacterial cells, the Lysate Clearance Filter Syringes completely remove SDS precipitates and clear bacterial lysates in a fraction of the time required for centrifugation. Yields vary according to plasmid copy number, E.coli strain, and conditions of growth, but 500 mL of overnight culture in LB medium typically produces 2.5 mg high-copy plasmid DNA. Up to 1 liter overnight culture may be processed when working with low-copy number plasmids. The product is suitable for automated fluorescent DNA sequencing, restriction endonuclease digestion, transfection of mammalian cells, and other manipulations.
This Protocol is designed to isolate 2.5 mg of high Copy-Number plasmids or 200 -500μg of low Copy-Number Plasmids from 500 mL overnight cultures using E.Z.N.A.™ Plasmid Mega Kit.
主要试剂
Absolute ethanol (96-100%)
主要设备
1. Centrifuge with swinging bucket rotor capable of 5,000 x g with adapter for 50 ml centrifuge tube
2. Vacuum pump capable of generate -200 to -600 mbar
3. Vacuum manifold with standard leur connector
4. 50 ml Centrifuge tube
5. 125 or 250 mL Bottle/Centrifuge
6. Centrifugation tube (i.e Nelgene 3120)
7. Vacuum Manifold (Cat No. Vac-08)
8. Ice
实验步骤
Growth of bacterial culture:
1. Culture volume: Inoculate 500 mL LB/ampicillin (50 ug/mL) medium placed in a 1-5 liter culture flask with E.coli carrying desired plasmid and grow at 37°C with agitation for 12-16 h. For best results use overnight culture as the inoculum. It is strongly recommended that an endA negative strain of E.coli be used for routine plasmid isolation. Examples of such strains include DH5α® and JM109®.
Note: Optimal growth conditions of bacteria is vital of obtaining maximal plasmid DNA yields. The best conditions are achieved by picking a single isolated colony from a freshly transformed or freshly plate to inoculate a 2-5mL starter culture containing the appropriate antibiotic. Incubate for ~8 hours at 37°C with vigorous shaking (~300rpm). Then used to inoculate appropriate volume of Pre-warmed liquid growth medium with antibiotic. Grow at 37°C for 12-16 hr with vigorous shaking(~300rpm).Using a flask or vessel with a volume of a least 3-4 times the volume of the culture and dilute the starter culture 1/500 to 1/1000 into growth medium. 600 Following overnight bacterial growth, an OD of 1.5~2.0 indicates a well-grown culture. For the 600 best result determination of OD for each culture is recommended. it is important to dilute the bacterial culture (10 to 20 fold) to enable photometric measurement in the linear range between 600 600. 0.1 and 0.5 OD . We recommend a bacterial density of between 2.0 and 3.0 at OD When using nutrient-rich media, care should be taken ensure that the cell density does not exceed 600 an OD of 3.0.
If using a frozen glycerol stock as inoculum, streak it onto an agar plate containing the appropriate antibiotic for single colony isolation. Then picking a single colony and inoculate the 2-5mL starter culture as described above.
Lyse bacterial cells with alkaline-SDS Solution:
2. Pellet up to bacteria in appropriate vessels by centrifugation at 5,000 × g for 10 min at room temperature.
3. Decant or aspirate medium and discard. To ensure that all traces of the medium are removed, use a clean paper towel to blot excess liquid from the wall of the vessel.
4. Add 20 mL Solution I/RNase A. Resuspend cells completely by vortexing or pipetting up and down.
Note: Complete resuspension of cell pellet is vital for obtaining good yield.
5. Add 20 mL Solution II, gently mix by inverting and rotating tube 7 times to obtain a cleared lysate. Incubate 3 minutes at room temperature.
Note: Avoid vigorous mixing as this will shear chromosomal DNA and lower plasmid purity. Prolonged incubation may lead to nicking of plasmid DNA. (Store Solution II tightly capped when not in use.)
6. Add 20 mL Ice-cold Neutralization Buffer, cover, and gently mix by inverting tube several times until a flocculent white precipitate forms.
Note: The mix must be mixed throughly. If the mixture appears still viscous, brownish and conglobated, more mixing is required to completely neutralize the solution. Complete neutralization of the solution is vital of obtaining good yields. Increasing centrifugation speed is helpful to completely remove the precipitated bacterial cell material. After centrifugation, a tightly packed cell debris pellet indicates efficient lysis.
7. Clear the lysate using Fastfilter Lysate Clearance Syringe: Immediately pour the lysate into the barrel of the Lysate Clearance Filter Syringe. Allow the cell lysate to sit for 2 minutes. The white precipitate should float to the top.
8. Hold the Lysate Clearance filter syringe barrel over the 125 or 250 m bottle/l tube and gently insert the plunger to expel the cleared lysate to the tube. Some of the lysate may remain in the flocculent precipitate, do not force this residual lysate through the filter.
Purify the plasmid with HiBind® Mega Column:
9. Measure the volume of the supernatant, add 1/3 volume of the PFC Binding Buffer. Mix throughly by vortexing.
10. Insert a HiBind DNA Mega column to the vacuum manifold.
11. Pour the cell lysate from step 9 into the HiBind® DNA Mega column and turn on the vacuum source to draw all the liquid through the column. Keep pouring the lysate until all the cell lysate pass through the column. Turn off the vacuum source.
12. Two wash the DNA, add 20 ml PFW Wash Buffer to the HiBind DNA Mega column and aply the vacuum to draw all the liquid through the column.
13. To wash the DNA, add 20 ml DNA Wash Buffer to the HiBind® DNA Mega column and apply the vacuum to draw all the liquid through the column. Keep adding additional 20 ml DNA Wash Buffer until all the liquid pass through the column.
14. Transfer the HiBind® DNA Mega column into a 50 ml centrifuge tube (supplied). Centrifuge at 5000 x g for 10 minutes to dry the membrane.
15. Place the HiBind® DNA mega column into a new 50 ml centrifuge tube (not supplied). Add 1.5-3 ml Elution Buffer (10mM Tris-HCl, pH 8.5) or water to the column. Incubate at room temperature for 5 minutes.
16. Centrifuge at 5000 x g for 5 minutes to elute the DNA.
真菌感染会对人类、动物和植物构成威胁,甚至带来严重后果。来自德国杜塞尔多夫海因里希-海涅大学(HHU)等机构的科学家,在一项最新研究中,阐明了真菌感染的一个重要分子机制。这一研究有望促进新型抗真菌药物......
细胞外基质(ECM)刚性是影响多种生物过程的重要机械线索。然而,对刚性传感的分子机制的理解受到当前细胞力测量技术的空间分辨率和力灵敏度的限制。2023年10月5日,武汉大学刘郑团队在NatureMet......
RNA介导的转录后基因调控在生命个体抵御外源入侵的过程中起到重要作用。Argonaute(Ago)蛋白是存在于古菌、细菌和真核生物中的一种蛋白。它为非编码小RNA提供锚位点,达到降解靶基因或者抑制翻译......
英国帝国理工学院的科学家与牛津纳米孔技术公司合作研制出一种新方法,可同时分析数十种不同类型的生物标志物,改变了对心脏病和癌症等疾病的检测,从而让临床医生收集到有关患者疾病的更多信息。研究成果25日发表......
体细胞突变是肿瘤发生的标志,可用于癌症的无创诊断。美国约翰·霍普金斯大学医学院绘制细胞游离DNA单分子全基因组突变图谱,用于癌症无创检测。该研究成果于近日发表在《NatureGenetics》杂志上,......
人们应用合成生物学手段已开发出精密的细胞生物传感器,可用于检测人类疾病。然而,生物传感器尚未被设计用于检测特定的细胞游离DNA序列和突变。美国加州大学圣迭戈分校等机构合作开发一种工程化细菌,可检测活体......
近日,中国农业科学院深圳农业基因组研究所农业基因组学技术研发与应用创新团队提出DNA数字存储纠错新算法,成功突破了冗余对纠错能力的限制,将大幅提升DNA存储纠错能力。相关研究成果发表在《国家科学评论》......
生物多样性丧失是三大环境危机之一。昆虫作为庞大且多样化的生物群体,几乎占据各种类型栖息地,在生态系统中扮演着重要角色。“SITE-100”国际大科学计划是中国科学院动物研究所研究员白明与英国自然博物馆......
上海交通大学化学化工学院/变革性分子前沿科学中心樊春海院士与王飞副教授近期发展了一种支持通用性数字计算的DNA可编程门阵列(DNA-basedprogrammablegatearray,DPGA),可......
美国西弗吉尼亚大学研究人员实现了在原子水平上观察合成DNA,从而了解了如何改变其结构以增强其剪刀功能。更多地了解这些合成DNA反应,或是未来解锁医学新技术的关键。研究结果发表在最近出版的《自然》子刊《......