Highresolutionnegativestaining
High resolution negative staining(From Valentine et al, 1968. Biochemistry 7:2143-52)Rationale: For the highest resolution with negative staining, there should be little or no support film, but some support is necessary to hold the protein. In this method the proteins are supported by a carbon film and "embedded" in a film of uranyl acetate. The film is cast on mica, which provides the cleanest possibl......阅读全文
AbC™-AntiMouse-Bead-Kit
实验概要The AbC™ Anti-Mouse Bead Kit provides a consistent, accurate, and simple-to-use technique for the setting of flow cytometry compensation when u
Immunofluorescence-Labeling-of-Cells
实验概要Antibodies are an important tool for demonstrating both the presence and the subcellular localization of an antigen. Cell staining is a very ver
Microscopes-in-Cell-Biology
Microscopes in Cell BiologyIntroductionMicroscopy has a major role in the study of cells. From the very beginning, researchers have tried to develop w
Staining-Procedure-for-Flow-Cytometric-Detection-of-Human-Cyclins
Staining Procedure for Flow Cytometric Detection of Human CyclinsThis is a standard protocol used at Pharmingen for Quality Control testing of the ant
Intracellular-Immunofluorescent-Staining-for-Flow-Cytometry2
Table 2: Human Cytokines: Intracellular Staining Quick GuideHuman Cytokines: Intracellular Staining Quick GuideHuman CytokineCell SourceActivationIncu
High-Molecular-Weight-Yeast-Liquid-DNA-Preparation
Purpose:To isolate intact, high molecular weight DNA from yeast cells for subcloning and rare cutting restriction enzyme analysis. One can expect a yi
Human-Alkaline-Phosphatase-staining-of-transgenic-embryo/tissue
AP Buffer:100 mM Tris-HCl, pH 9.5100 mM NaCl10 mM MgCl2PTM:PBS0.1% Tween-202 mM MgCl2Since this is generally done in conjunction with lacZ staining, e
High-Speed-SI测试与仿真讨论
随着高速设计越来越普遍,信号完整性设计在产品开发中也受到了越来越多的重视。信号完整性的测试手段种类繁多,有频域,也有时域的,还有一些综合性的手段,涉及的仪器也很多,因此熟悉各种测试手段的特点,以及根据测试对象的特性和要求,选用适当的测试手段,对于选择方案、验证效果、解决问题等硬件开发活动,都能够大大
Restriction-Digests-of-High-Molecular-Weight-Yeast-DNA
Purpose:To perform restriction digests of YACs for mapping using rare cutting enzymes or more conventional restriction endonuclease digestion.Time req
Betagal-staining-of-eukaryotic-cells-in-vitro
(Modification of methods of Dr. Seong-Seng Tan and Promega's "Protocols and Applications Guide")Cells previously transfected with a lac Z construc
银染(silver-staining)操作规程
实验原理:在碱性条件下,用甲醛将蛋白带上的硝酸银(银离子)还原成金属银,以使银颗粒沉积在蛋白带上。染色的程度与蛋白中的一些特殊的基团有关,不含或者很少含半胱氨酸残基的蛋白质有时候呈负染。银染的详细机制还不是非常清楚。 试剂:乙醇、冰醋酸、乙酸钠、硫代硫酸钠、硝酸银、碳酸钠、甘氨酸或EDTA.Na
想更健康?别坐着,起来high!
对于大部分上班族、学生党来说,每天工作、学习都是坐着。有研究表明,在觉醒时间为14到15小时的一天里,我们有55%到75%的时间是坐着的。一般而言,连续静坐超过两小时,身体就会出现亚健康的信号。每天累积静坐8小时以上,多项疾病的风险都会明显升高。像葛大爷这样坐(瘫)着很舒服,但是同时你的身体却在
罗氏诊断购买AvanSci-Bio公司组织分离ZL技术
美国时间2014年12月10日,罗氏诊断宣布与AvanSci Bio公司签署了一项收购协议,购买与高性能显微组织滑动式切片分离的相关产品,包括仪器、软件及研究人员使用的耗材,以及临床提取、具有较高精确度和纯度用于后续分子分析的特定区域,包括实时PCR、微阵列和测序。 AvanSci
Use-of-the-B.D.-FACS-or-Calibur-Flow-Cytometers
Reservations:Schedule time on a cytometer (FACS or Calibur) by filling in the calendar at the flow lab. Don't grossly overbook since we have to pa
Gram-Stain-(+\)
MaterialsColonies of bacteria from Exercise 12.2ToothpicksCrystal violetGram''s iodine95 ethanolSafraninMicroscopes with oil immersionProcedur
Light-Microscopy
The light microscope, so called because it employs visible light to detect small objects, is probably the most well-known and well-used research tool
AbC™-AntiMouse-Bead-Kit
实验概要The AbC™ Anti-Mouse Bead Kit provides a consistent, accurate, and simple-to-use technique for the setting of flow cytometry compensation when u
Detection-Of-Cell-Viability-And/Or-Apoptosis-By-Flow-Cytometry-(FACS)
Viable cells are cells that when allowed to continue beyond the timepoint of examination will stay alive. Besides live and healthy cells, cells in ear
Gram-Stain-(+\)
实验概要细菌的革兰氏染色技术实验材料Colonies of bacteriaToothpicksCrystal violetGram's iodine95% ethanolSafraninMicroscopes with oil immersion实验步骤1. Before staini
Alexa-Fluor®-488-Annexin-V/Dead-Cell-Apoptosis-Kit
实验概要Apoptosis is a carefully regulated process of cell death that occurs as a normal part of development. Inappropriately regulated apoptosis is imp
免疫细胞表面抗原分子CD家族对照表(CD1CD247)
Exalpha Biologicals produces and sells products for Life Science Research, including monoclonal and polyclonal antibodies, for use in immunohistochemi
LIVE/DEAD®-Fixable-Dead-Cell-Stain-Kits
实验概要The LIVE/DEAD® Fixable Dead Cell Stain Kits use a novel method to evaluate the viability of mammalian cells by flow cytometry. These assays are
细胞周期的流式细胞伩检测实验方法(PI,Brdu)2
B.3. COMMENTARY B.3.1 Background information The critical steps in the methodology are cell fixation, permeabilization and the concentrations of anti-
Preparation-of-High-Titer-Adenovirus-in-P11-cells
adapted from Cell Biology, A Lab Manual, second edition, volume 1 -Grow up P11 cells in 15 cm plates to 70 – 80% confluence. -Infect cells with a MOI
Miniprep/Kitfree-highthroughput-protocol
BackgroundThis protocol is adapted from "Molecular Cloning: A Laboratory Manual", Second Edition, Sambrook, Fritsch, and Maniatis. It is a quick, inex
Hybridization-of-High-Density-Arrayed-BAC-Nylon-Filter-Blots
Protocol for hybridization of high density arrayed Bacterial Artificial Chromosome nylon filter blots with 100 PCR isolated Unigene cDNA inserts, pool
Histochemical-staining-of-sea-urchin-embryos-for-(AP)-enzyme-activity
Histochemical staining of sea urchin embryos for alkaline phosphatase (AP) enzyme activity1. Obtain embryo samples, tube of AP substrate buffer and tu
Whole-mount-antibody-staining-ofzebrafish-embryos-formarkers-ofsegmentation
1. Dechorionate 26 hr embryos (pharyngula stage) carefully with two fine forceps.Transfer to fixative (1% formaldehyde in PBS). Fix for 1 hour rocking
What-Does-It-Take-to-Produce-High-Quality-Pipettes-and-Tips-……
February 27, 2018 - GreifenseeAs scientists, you depend on quality pipettes and tips for accurate and reliable experimental results, but have you
AbC™-AntiRat/Hamster-Bead-Kit
实验概要The AbC™ anti-Rat/Hamster Bead Kit provides a consistent, accurate, and simple-to-use technique for the setting of flow cytometry compensation